Advanced Projection Microscope

Advanced Stereo Binocular

Analgesiometer (Eddy's Hot Plate)

Auto Coater

Ball Mill Motor Driven

Bicycle Ergograph

Binocular Metallurgical Microscope

Binocular Microscope Co-axial

Camera Lucida

Camera Lucida Prism Type

CCTV SYSTEM

Centrifuge Machine

Close Type Scoops/Spatula

Colony Counter

Conical Percolator

DEHUMIDIFIER (Routine Model)

Dies Punches Cabinet

Digital Bulk Density Apparatus

Digital Potentiometer

Dissection Microscope (Entomological)

Dissection Microscope Entomological

Dissolution Rate Test Equipment

Dissolution Rate Test Equipment

Double Demonstration Eye Piece

DOUBLE JACKETED ST. STEEL PASTE MAKING KETTLE

Double Unit Organ Bath

Drum/Trolley

Electronic Stimulator

Eye Piece and Objectives

Filter Press

Fix and Revolving Chairs

Friability Test Apparatus

Friability Test Apparatus

Fume Hood

Heating Mantles

Histamine Chambers

Hot Air Sterlizer (Oven)

Hot Plates

In Process Container

Inclined Co-Axial Microscope

Inclined Medical Microscope

Inclined Microscope Deluxe

Inclined Stereo Microscope

Incubators

Karl Fischer Apparatus for Moisture Content Determination

Lamp with Stand

Mechanical Stirrer (laboratory Stirrer)

Medical Microscope Junior with Moveable Condenser

Medical Pathological Microscope

Microscope Inclined Stereo

Microscope Inverted Tissue Culture

Microscope Lamp

Moisture Balance

Mopping Trolley

Motor Driven Disintegrator

Ointment / Cream Filling Machine

Open Type Scoops Measuring Jar Spatula

Operation Table Large Size

OSCILLATING GRANULATOR

PASTE KETTLE WITH TILTING SYSTEM ( CAPACITY 50 Ltrs.)

Pole Climbing Apparatus

Polishing Pan

POUCH FILLING & SEALING MACHINE (AUTOMATIC)

Prescription Balance

Rabbit Holder

Rapid Mixer Granulator

Rotarod Apparatus

Rotary Vacuum Film Evaporator (Buchi Type)

Semi Automatic Counting Machine.

SEMI-AUTOMATIC TABLETS /CAPSULES COUNTING & FILLING MACHINE

Sherrington Rotating Drum

Sieve Shaker (Hand Operated)

Sieves For Powder Shifting

Sieves Scoop Spatula Trolley

Soxhlet Extraction

Spirometer

Stereo Dissecting Microscope

STRIP PACKING MACHINE

Student Microscope

Student Microscope Single Nose

Student Microscope Triple Nose

Student Organ Bath

Student Projection Microscope

TABLET / CAPSULE - COUNTER

Tablet Coating Pan

Tablet Hardness Tester Monsanto Type

Tablet Hardness Tester Pfizer Type

Tablet Triturate Moulds

Tele-thermometer

Tilting Paddle Dust Bin

Tincture Press

Tool Box

Tray Dryer

Trinocular Co- Axial Microscope

Trinocular Stereo Zoom Microscope

U.V. Inspection Cabinet Long Wave

V BLENDER

Vortex Mixer

Water Deionization Apparatus

Y-Maze

Product Details
Item Name : Rapid Mixer Granulator
Category : Pharmacy Equipments

APPLICATION :-

MIXING BOWL & COVER: S.S. 304 bowl design in three sections i.e Flat bottom, Cylindrical mid portion and conical top portion for efficient mixing operation & provided with counter balanced lid. Lid provided with vents, view ports & charging openings.
MAIN IMPELLER & DRIVE: The main impeller consists of dual speed 750/1500 synchronous dual HP TEFC motor, coupled through a belt drive to a worm reduction gearbox with chain coupling. The impeller is designed to provide mixing at the bottom and at the centre of the bowl and is driven through a specially designed bearing housing that facilities inside wash facility for quick change over and also prevents leakage of powder from bottom entry and leads to longer life of gear box. 
CHOPPER: The chopper drive consists of dual HP Dual speed (1440/2800 synchronous speed) TEFC MOTOR. The motor shaft is of S.S. and the chopper has specially designed 4 blade S.S. Impeller. The shaft is integral with the motor. The assembly mounted horizontally into the bowl.
DISCHARGE PORT: The discharge port is mounted horizontally into the bowl with vertical downward opening. The opening is operated by pneumatic cylinder and discharged can be regulated for required opening.
MOUNTING: A sturdy M.S. channel frame is used to house the drive assemblyat the bottom. The bowl is mounted on the top. A S.S. staircase and railings are provided for the platform. The platform is half covered with S.S, dimpled plates. For safe movement of operater and the area under the bowl is covered with S.S.
The entire body is covered from the sides by suitable S.S. covers.
CONTROL PANEL: The control panel is mounted on platform and is provided with
Actuators for ON/OFF, slow, fast operation.
Auto / manual controls.
Timer.
Indicator Lights.
Ammeter/ voltmeter for both motors.
Controls for discharge opening / closing.
Air regulator & Pressure gauge & air filter. Optionally a PLC based control Panel can be Provided.
MAIN PANEL: Main panel consists of all prewired connections and it has only to be connected to the electrical supply. The circuits consist of MCCB and the relay. Wires coming out of the connections are numbered for easy recognition.
SPECIAL FEATURES:
Air purged shaft seals eliminating powder entering the seal.
Built in cleaning system for both shaft seals.
Layouts to suit individual requirements possible.
Machine can be provided with loading & unloading units to form an assembly line & reduce material handling (Optional feature)Machine can be provided with loading & unloading units to form an assembly line & reduce material handling (Optional feature)
Fenner taper lock pulley on main drive to reduce vibration and better transmission efficiency.
Main Bearing Housing provided with 3 nos Oil Seals and sleeve to minimize powder leakages / cross contamination. Chopper motor with built in S.S. shaft to eliminate roller, bearings and reduce maintenance. 
Main panel provided with pressure switch control for proper functioning of the machine at desired pressure of air only to prevent powder entry into impeller and eliminates jamming of impellers. 
      Circuit provided with interlock contactors so that chopper cannot operate directly, independently. 
      Discharge plunger provided with 3 position solenoid valves to open and close at desired levels, thereby regulating the discharge and preventing discharge of large lumps. 
      Pneumatic circuit provided with non return valve and water inlet./ outlet connections for facilitate washing of the main impeller assembly without dismantling, to facilitate faster change over.
 
9) SAFETY FEATURES:
      Locking arrangement for motor to eliminate accidentally starting with open lid. 
      Enclosed moving parts.
 
10) PNEUMATIC SYSTEM: The pneumatic systems require air pressure of 3 to 5 Kgs/sq cm. It is used for Operating the discharge valve (opening & closing) Air purging of chopper drive and main impeller